XY-LJ02 Timer Relay Delay Switch Module รีเลย์ไทม์เมอร์ พร้อมจอแสดงผล
XY-LJ02 Timer Relay Delay Switch Module รีเลย์ไทม์เมอร์ พร้อมจอแสดงผล
Timer Relay Delay Switch Module รีเลย์ไทม์เมอร์ พร้อมจอแสดงผล (XY-LJ02) ใช้ไฟเลี้ยง 6-30V ขับกระแสได้สูงสุด 5A สามารถตั้งเวลาได้ตั้งแต่ 0.1 วินาที – 9999 นาที
ตัวอย่างวิธีใช้ https://www.youtube.com/watch?v=s4oNCpH_I0E
Product Highlights:
– Display with LCD two columns Can display parameters directly;
– Trigger mode: high and low level, switch quantity. meet most of the needs.
– Power supply: 6~30V.
– Parameters can be modified via UART.
– Stop button to provide emergency stop function.
– 5 minutes without any operation into a low-power state. Any action wakes up.
– OP/CL/LOP params can be modified individually
– All parameters are automatically saved by power off.
– Working Mode Introduction(P1~P7)
Operation Modes
– P0: After the signal is triggered, the relay conduction in OP time then disconnects; In the OP time, the signal is invalid.
– P1: After the signal is triggered, the relay conduction in OP time then disconnects; In the OP time, the signal triggers a new timer.
– P2: After the signal is triggered, the relay conduction in OP time then disconnects; In the OP time, signal trigger reset timer, relay disconnected, and stop timing.
– P3: After the signal is triggered, the relay disconnects the CL time, and then the relay conduction.
– P4: After the signal is triggered, the relay conduction the OP time, and then the relay disconnects the CL time, and then loops the above action, gives the signal again in the loop, relays disconnect, stops the timer; and the number of cycles (LOP) can be set; End of a cycle, keep relay disconnected;
– P5: After the signal is triggered, the relay disconnects the CL time, and then the relay conduction the OP time, and then loops the above action, gives the signal again in the loop, relays conduction, stops the timer; and the number of cycles (LOP) can be set; End of a cycle, keep relay conduction;
– P6: No trigger signal after power-on, After the relay conduction OP time, the relay disconnects the CL time, and then loops the above action, the signal is invalid in the loop, the number of cycles (LOP) can be set; End of a cycle, keep relay disconnected;
– P6: No trigger signal after power-on, After the relay, disconnects the CL time, the relay conduction OP time, and then loops the above action, the signal is invalid in the loop, the number of cycles (LOP) can be set; End of a cycle, keep relay conduction;
– P8: Signal hold function: The signal is maintained, the timing is cleared, and the relay conduction; when the signal disappears, the relay disconnects after the timing OP; during the timing, there is another signal and the timing is cleared;